The ASPYRE® AT is a family of flexible, compact and scalable smart SCR power controllers. It features multiple advanced firing and control mode algorithms combined with sophisticated diagnostics. The ASPYRE AT integrates easily with EZ-ZONE® RM, PM PLUS® and RMA PLUS™ controllers as part of a Watlow® ecosystem solution.
Key component of a Watlow ecosystem solution
High accuracy current and voltage measurement
Integrated, scalable solution
Industry-leading design and serviceability
100KA short circuit current rating (SCCR)
c-UL® 508 Listed
Closed-loop control on: Voltage, current or power
Load firing modes: Zero-cross, burst fire, phase angle, soft start
Open heater and shorted SCR indication
Integrated USB for configuration
Heater bakeout
Cooling options
| Power Bases | Single-phase, 1 controlled leg |
|---|---|
| Load Amp Range | 12A, 24A and 48A options (see derating curves |
| SCR and Amperage Rating | SCCR rating 100,000A up to 480VAC with coordinated fusing SCCR rating 10,000A up to 240VAC with recommended circuit breaker Power dissipation: Approximately 1 to 1.2 watts per amp Leakage current: 1mA at 25°C |
| Line and Load Voltage Range | 100 to 480V |
| Voltage Frequency | Automatically compensates for 47 to 63Hz |
| Controller Operating Supply Voltage | 24VDC, 6W 6VA per ASPYRE AT unit Maximum 10 units powered via terminal screw and backplane connector Use split-rail configuration when more units are required |
| Voltage and Current Measurement Accuracy | ±2% of range |
| Control Modes | Voltage, voltage squared, current, current squared, power |
| Output Control Firing Types | Fixed time-base zero crossing Variable time-base zero crossing (burst firing) Phase angle |
| Digital Inputs and Outputs | Independently user-configurable as input or switched DC output Update rate: 10Hz Input type: User-selectable, dc voltage or dry contact Input logic: On ≥ 4VDC, off ≤ 1VDC, 30VDC max Output voltage: 24V (based on the supply voltage) Output: 100mADC ma |
| Analog Input | Voltage: 0-10VDC, 15kΩ impedance Current: 4 to 20mA, 0 to 20mADC, 100Ω impedance |
| Analog Output | 0 to 20mADC ±120μA or 4 to 20mADC into 500Ω max. load with 30μA nominal resolution 0 to 10VDC ±60mV into a 500Ω min. load with 15mV nominal resolution |
| Electromechanical Relay Output | Form C, 5A resistive load 100,000 cycles at 24VDC, 120/240 VAC 125VA pilot duty 120/240VAC 25VA 24VAC/DC |
| Connectivity | EIA 485, Modbus® RTU (option) USB device EtherCAT® ETG (future option) Modbus® TCP (future option) EtherNet/IP™ (future option) ProfiNet (future option) |
| Diagnostics | Open load circuit (including heater break) partial load failure, SCR short circuit, current limit, thermal alarm, line voltage loss |
| Operator Interface | 4 discrete LED indicators for status monitoring |
| COMPOSER® PC Configuration Software | Connects via USB port Easy-to-use test drive screen Function block diagram programming |
| Cooling Options | DIN-rail heat sink for convection cooling Base plate for use with customer supplied heat sink |
| Control Terminals | Terminal blocks are touch safe, removable, 22 to 12 AWG, 5 in.-lb. (0.6 Nm) torque, 1/8 in. (3.5 mm) flat blade screw driver |
| Line and Load Terminals | Compatible with crimp lug terminals or bare wire, 12 to 6 AWG, 24 in.-lb. (2.7 Nm) torque, 1/8 in. hex driver |
| Ground Terminal | Recommended 14 to 10 AWG with UL® Listed (ZMVV) #8 ring or spade crimp lug, 15 to 17 in.-lb (1.7 to 1.9 Nm) torque, , 1/4 in. (6.5 mm) flat blade screw driver |
| Mounting | Panel mounting with screws or DIN rail No. 8 (M4) fastener DIN rail: 35mm x 7.5mm |
| Environment | 0 to 60°C (single unit) or 55°C (multiple units) see derating curves 5 to 90% RH (relative humidity), non-condensing |
| Agency Approval and Regulatory | UL® 508 Listed c-UL® Listed CE EMC Directive Class A Emissions CE Safety Directive EN 60947-4-3 IP20 RoHS 2015-863-EU W.E.E.E 2012-19-EU Enclosure Flammability Rating: 94-V0 |